Dalian Yheng Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of remote type electromagnetic flow meter in China. Welcome to buy high quality remote type electromagnetic flow meter in stock here from our factory. If you have any enquiry about customized service, please feel free to email us.
|
Parameter Category |
Specification |
|
Basic Principle |
Faraday's Laws of Electromagnetic Induction |
|
Measuring Medium |
Electrically conducting liquids, caustic liquids, liquid-solid mixtures |
|
Applicable Industries |
Petroleum, chemical engineering, pharmacology, papermaking, electric power, environmental protection, water/waste water, food, agriculture, effluent |
|
Nominal Meter Size |
6 mm ~ 2800 mm (0.2 inch ~ 110 inch) |
|
Working Pressure |
0.6, 1.0, 1.6, 2.5, 4.0, 6.4, 10, 16, 25 MPa |
|
Accuracy |
±0.25%, ±0.5% (on request) |
|
Minimum Conductivity |
>5 μs/cm |
|
Fluid Temperature |
Rubber liner: 0~70°C FEP liner: -20~180°C PTFE liner: -40~180°C |
|
Ambient Temperature |
-30°C ~ 60°C (-22°F ~ 140°F) |
|
Relative Humidity |
≤90% r.h |
|
Liner Materials |
Rubber, PTFE, FEP, PFA - PFA/PTFE: High chemical resistance, high temperature capability - Rubber: Abrasion resistance, wide applications |
|
Electrode Materials |
316L Stainless Steel, Hastelloy (HB,HC), Tantalum, Titanium, Platinum, Tungsten Carbide - 316L: Good corrosion/abrasion resistance (not for H₂SO₄/HCl) - Hastelloy: Better corrosion resistance, high strength (suitable for slurry/oxidizing fluids) - Tantalum: Excellent chemical resistance (not for fluosilicic/HF/NaOH) - Titanium: Good corrosion/abrasion resistance (suitable for seawater, not for HF/H₂SO₄) |
|
Output Signals |
1. Current: 4~20mA (load resistance ≤500Ω) 2. Frequency: 0~10KHz 3. Pulse: 0.001~1000 Ltr/Pulse 4. Communication: RS-485, HART 5. Alarm: High/low alarm output (load current ≤30mA for ALMH) |
|
Supply Power |
AC: 85~265VAC (power <10W) DC: 18~36VDC (power <7.5W) |
|
Flow Rate Range |
Refer to meter size (e.g., DN10: 0.014~3.39 m³/h; DN1000:141~33912 m³/h) |
|
Flow Unit Options |
L/s, L/m, L/h, m³/s, m³/m, m³/h, USG/s, USG/m, USG/h, kg/s, kg/m, kg/h |
|
Communication Protocol |
RS-485: MODBUS-RTU (default), MODBUS-ASCII Baud rate: 1200/2400/4800/9600 (default)/19200/38400 Data bit: 7/8 (8 default; 7 unavailable for RTU) Check mode: None (default)/Odd/Even Device ID: 1~247 (1 default) |
|
Calibration Functions |
4mA calibration, 20mA calibration, zero calibration (requires full pipe & static fluid) |
|
Installation Requirements |
1. Pipe must be fully filled with liquid at all times 2. Inlet straight pipe: ≥3×DN; Outlet straight pipe: ≥2×DN (≥5×DN/10×DN for special fittings) 3. Avoid pulsating flow, electrical interference (motors/transformers/VFDs), air bubbles & precipitates 4. Terminal box mounted above piping (prevent water ingress) 5. Proper grounding (per national/local electrical codes; grounding rings/lining protectors for lined/non-conductive pipes) |
Features
● Highly intelligent Design
● Multi-electrode structure
● High accuracy
● No moving parts
● Wide operating range
● Robust and Intelligent Design
● High Accuracy & No Moving Parts
● Diverse Power Supply and Outputs
● Enhanced Electrode and Excitation Technology
● Advanced Diagnostics and Protection
Applications
The remote type electromagnetic flow meter stands out as the ultimate solution. Its intelligent features, robust protection mechanisms, and versatile output options ensure that it meets the rigorous demands of modern industry while providing peace of mind through reliable, long-term operation.






Hot Tags: remote type electromagnetic flow meter, China remote type electromagnetic flow meter manufacturers, suppliers, factory, electromagnetic flow meter, Flanged connction Electromagnetic Flow Meter, Insertion Type Electromagnetic Flow Meter, RS485 Remote Type Electromagnetic Flow Meter, Split Type Electromagnetic Flow Meter, Threaded Electromagnetic Flow Meter