RS485 Modbus Residual Chlorine Sensor

RS485 Modbus Residual Chlorine Sensor

The sensor can be used to measure the concentration of disinfectants such as free chlorine, chlorine dioxide (high purity), and ozone. It is mainly used in application scenarios such as tap water, pipe networks, secondary water supply, water ends, and swimming pools. The electrode has a built-in ARM processor and high-efficiency filtering algorithm, which can effectively avoid the interference of noise. It has an RS-485 interface, which is convenient for access to computers and network monitoring systems.
Send Inquiry

Dalian Yheng Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of rs485 modbus residual chlorine sensor in China. Welcome to buy high quality rs485 modbus residual chlorine sensor in stock here from our factory. If you have any enquiry about customized service, please feel free to email us.

 

Product Features:

1. We use electronic and chemical sensors, there is no reagent consumption and pollutant emissions;

It is designed without film. So there is no need to replace the membrane head and adding electrolyte;

We designed three electrodes, there are zero point stability and high sensitivity;

The built-in high-precision sampling circuit makes the sensor linearity good;

5. When the pH does not change much, it can be accurately compared with the DPD measurement method.

Technical parameters:

System

Power supply

DC 9-28V

Power

0.5W

Measurement parameters

free chlorine, chlorine dioxide (high purity), ozone

Communication interface

RS485 + 4-20mA

Electrode Material

Platinum, Silver chloride

Design life

>18 months

Water sample flow rate

>400mL/min, and the flow rate needs to be kept stable.

Temperature range

-5 - 45°C (Non-freezing)

Withstand pressure

<0.1MPa

Disinfectant

(free chlorine/

chlorine dioxide/

Ozone/

Measurement method

Reagent-free, electrochemical, three-electrode amperometric assay system

Range

0-5mg/L (default), 0-20mg/L, 0-100mg/L

Resolution

0.001mg/L

Detection limits

0.030mg/L or less

Accuracy

± 3% (DPD comparison error ± 10% or ± 0.05mg/L, whichever is greater)

Repeatability

± 3%

Corresponding time(T90)

≤ 90s

Calibration method

Single-point calibration, two-point calibration

Sample pH range

4 - 9

Temperature

Measurement method

Thermistor method

Range

-5 - 60℃

Resolution

0.1℃

Accuracy

±0.4℃

Repeatability

0.2℃

Corresponding time(T90)

≤ 25s

Calibration method

Single-point calibration